详细信息
ANALYSIS OF SEEPAGE FLOW IN A CONFINED AQUIFER WITH A STANDING COLUMN WELL ( SCI-EXPANDED收录) 被引量:20
文献类型:期刊文献
中文题名:ANALYSIS OF SEEPAGE FLOW IN A CONFINED AQUIFER WITH A STANDING COLUMN WELL
英文题名:ANALYSIS OF SEEPAGE FLOW IN A CONFINED AQUIFER WITH A STANDING COLUMN WELL
作者:Li Min[1];Diao Nai-ren[2];Fang Zhao-hong[2]
机构:[1]Guangdong Ocean Univ, Coll Engn, Zhanjiang 524088, Peoples R China;[2]Shandong Jianzhu Univ, Ground Source Heat Pump Res Ctr, Jinan 250101, Peoples R China
年份:2007
卷号:19
期号:1
起止页码:84
中文期刊名:Journal of Hydrodynamics
外文期刊名:JOURNAL OF HYDRODYNAMICS
收录:SCI-EXPANDED(收录号:WOS:000208247700013)、CSTPCD、、Scopus、CSCD2011_2012、WOS、CSCD
基金:Project supported by the National Natural Science Foundation of China (Grant No. 50476040).
语种:英文
中文关键词:ground source heat pump;standing columnwell;seepage flow;heat transfer
外文关键词:ground source heat pump; standing column well; seepage flow; heat transfer
中文摘要:The standing column well for ground source heat pump systems is a promising technology with high efficiency and environmental benefit, where groundwater is drawn from the bottom of a well and then re-injected to its top after transferring heat with heat pumps. Heat transfer analysis of great significance and aquifer involves complex problems. Determining the groundwater seepage flow is a precondition to solve the energy equation describing the heat transfer of the system. Only when piezometric head is obtained, the seepage velocity can be determined according to Darcy's law. In this article the groundwater seepage flow in an axial symmetrical geometry was studied under the assumption that gross groundwater flow is neglected. An analytical solution of the groundwater seepage flow for a confined aquifer was acquired by using the integral transform method, which may provide a foundation for heat transfer analysis of the standing column well system.
外文摘要:The standing column well for ground source heat pump systems is a promising technology with high efficiency and environmental benefit, where groundwater is drawn from the bottom of a well and then re-injected to its top after transferring heat with heat pumps. Heat transfer analysis of great significance and aquifer involves complex problems. Determining the groundwater seepage flow is a precondition to solve the energy equation describing the heat transfer of the system. Only when piezometric head is obtained, the seepage velocity can be determined according to Darcy's law. In this article the groundwater seepage flow in an axial symmetrical geometry was studied under the assumption that gross groundwater flow is neglected. An analytical solution of the groundwater seepage flow for a confined aquifer was acquired by using the integral transform method, which may provide a foundation for heat transfer analysis of the standing column well system.
参考文献: