Reusable surface plasmon resonance sensor for rapid detection of Cu2+ based on modified-chitosan thin film as an active layer  ( SCI-EXPANDED收录)   被引量:13

文献类型:期刊文献

英文题名:Reusable surface plasmon resonance sensor for rapid detection of Cu2+ based on modified-chitosan thin film as an active layer

作者:Wang, Wenhua[1];Zhou, Xinlei[2];Wu, Shengxu[3];Li, Sidong[4];Wu, Weina[5];Xiong, Zhengye[1];Shi, Wenqing[1];Tian, Xiuyun[1];Yu, Qingxu[2]

机构:[1]Guangdong Ocean Univ, Sch Elect & Informat Engn, Zhanjiang 524088, Guangdong, Peoples R China;[2]Dalian Univ Technol, Sch Optoelect Engn & Instrumentat Sci, Dalian 116024, Peoples R China;[3]Guangdong Inst Anal, China Natl Analyt Ctr, Guangzhou 510070, Guangdong, Peoples R China;[4]Guangdong Ocean Univ, Sch Chem & Environm, Zhanjiang 524088, Guangdong, Peoples R China;[5]Guangdong Ocean Univ, Sch Math & Comp Sci, Zhanjiang 524088, Guangdong, Peoples R China

年份:2019

卷号:286

起止页码:59

外文期刊名:SENSORS AND ACTUATORS A-PHYSICAL

收录:SCI-EXPANDED(收录号:WOS:000457951300008)、、WOS

基金:This work was supported by the Science and Technology Planning of Guangdong Province (NO. 2015A030401094), and the National Natural Science Foundation of China (NO. 61727816, NO. 61520106013).

语种:英文

外文关键词:Surface plasmon resonance; Modified-chitosan; Composite film; Reutilization; Copper ions

外文摘要:In this article, a reusable surface plasmon resonance (SPR) sensor for rapid detection of copper ions (Cu2+), based on optimized silver/gold (Ag/Au) composite film modified by modified-chitosan (MCS) thin film as an active layer, was achieved. We employed a four-layer Kretchmann semi-cylindrical prism configuration and induced a reference beam into the experimental system to improve the sensitivity and stability, and investigated the cross-linking technique of CS solution, the spin coating process of MCS film, the stability of active layer, the rebirth power of SPR sensor, and the detection for trace Cu2+. The rate of swelling or dissolution of MCS film after flushing sensor chip for four times is less than 9 x 10(-4)/min, and the decline of signal value is less than 1.5% after MCS film adsorbing Cu+2 and multiple flushing. The elution and capacity rates are above 96% after five times of elution for the sensor by EDTA solution with 0.5mmol/L. Within 1-5ppm, the SPR sensor was found to possess sensitivity of 0.7271ppm(-1). The LOD is 18ppb for the trace Cu2+. The present SPR sensor not only could be used in trace monitoring of Cu2+ but also could be extended to other potential applications. (C) 2018 Elsevier B.V. All rights reserved.